autoreclosing device

中文翻译自动重合闸装置

同义词释义

    1)auto-reclosing device,自动重合闸装置2)synthetical reclosing device,综合自动重合闸装置3)periodicautomatic-reclosing equipment,周期性自动重合闸装置4)reclosing device,重合闸装置5)self-adapting automatic recloser,自适应重合闸装置6)auto-reclosing,自动重合闸

用法例句

    Measures of using automatic stand-by power switching devices and auto-reclosing devices with protection values reasonably set are proposed to solve th.

    针对现有地区电网的接线方式和保护配置,比较全面地分析了110kV双电源变电站、线路-变压器组变电站、有电源上网的变电站在不同运行方式及故障方式下的运行可靠性,对运行实践中出现的问题,提出了采用备用电源自动投入装置、自动重合闸装置及合理设定保护定值等方法来解决的方案,该方案在惠州电网变电站运行的实践中得到验证。

    It also raises several thoughts and suggestions about when to switch the automatic reclosing device during the bypass bus charging.

    根据电磁操作机构断路器的工作原理,提出其在转冷备用和转检修工作中熔断器的操作步骤和对旁路母线充电时自动重合闸装置投、退问题的思考和建议,以规范变电倒闸操作,提高电网运行的安全性。

    In order to avoid 500kV Sichuan Hong-Long double-circuit lines on same tower tripping simultaneously because of out-phase instantaneous fault and to enhance the reliability of power supply, a new relay protection and self-adapting automatic recloser of double-circuit lines on same tower has been developed.

    为避免四川电网洪龙 5 0 0kV同塔双回输电线路因异名相瞬时故障而同时跳开 ,增大系统供电的可靠性 ,研制出新型的同塔双回输电线路继电保护及自适应重合闸装置 ,并对其进行了RTDS实时仿真试验。

    Implementation of intelligent auto-reclosing with DSP;

    用DSP实现智能化自动重合闸

    Case study of power system auto-reclosing logic;

    电力系统自动重合闸的案例逻辑分析

    A new technique of employing auto-reclosing technology for single-phase-to-ground fault clearing in non-valid grounded power systems is also presented.

    通过小电流接地电网单相接地选线装置得到的现场数据的分析,提出了除瞬间接地故障和永久性接地故障之外的第3种接地故障——短时接地故障的概念,提出了在小电流接地系统中引入面向单相接地故障的自动重合闸技术(简称接地重合闸)的新技术,它同样适用于谐振接地系统中,有利于故障的快速消除,提高了系统的供电可靠性。

    periodic-automatic reclosing equipment

    周期性自动重合闸装置

    Discussion on the Relay Protection and Auto Reclosing Device and Their Configuration for High Voltage Transmission Line

    论高压输电线路继电保护与自动重合闸装置与配置

    network tripping and reclosing device

    电力网自动跳闸和重合闸装置

    Automatic Re-closing Devices in Power Supply System and the BZT Device

    供电系统自动重合闸及备用电源自动投入装置

    Influence of matching of measurement and control device D25 with CZX-12A on recloser of 220 kV line

    测控装置D25与CZX-12A配合对220kV线路重合闸的影响

    brake block adjusting gear

    制动器闸瓦调整装置

    The Research and Improvement of High-voltage Transmission Line Microcomputer Reclosing Device;

    高压输电线路微机重合闸装置的研究与改进

    Single-pole Adaptive Reclosure Based on Transient Component;

    基于暂态分量的自适应单相自动重合闸研究

    Application Study on Adaptive Single Automatic Reclosing Based on Intelligent Control;

    智能式自适应单相自动重合闸的应用研究

    A Survey on Present Achievements of Single-pole Adaptive Recloser Technology

    自适应单相自动重合闸技术研究现状综述

    The Application of Single-phase (or Combination Type) Autoreclosure in 220 kv High Voltage Electrical Transmission Systems.

    单相(综合)重合闸装置在220千伏高压电网上的应用

    Researches on the Coordination between Autoreclose Circuit Breaker and Relay Protection;

    自动重合闸(ZCH)与继电保护配合技术研究

    The development of automatic reclosing made the unattended substation practical.

    自动重合闸的研制使无人值班变电站得以实现。

    Improvements of reclosing circuits during upgrading substation automation systems

    变电所自动化升级中的重合闸回路改造

    Design of Contactless Autoreclosing Controller for Rural Distribution Network

    农村配电网无触点自动重合闸控制器的设计

    On Development of the-same-term Switch Equipment Based on 89C51;

    基于89C51的发电厂同期合闸装置研制

    Analysis on Coordination of Automatic Reclosing in Line-transformer Strings with 3/2 Connection

    3/2接线特殊运行方式下线变串自动重合闸配合分析

    Coordination of line detection with automatic re-closing in DC traction power supply systems

    直流牵引供电系统线路检测与自动重合闸的配合